摘要 :Graphical abstractDisplay OmittedAbstractAmong all the senses, olfactory system of mammals is the least characterised as far as the mechanisms of odour identification are concerned. The results of recent investigations allow bette...
展开Graphical abstractDisplay OmittedAbstractAmong all the senses, olfactory system of mammals is the least characterised as far as the mechanisms of odour identification are concerned. The results of recent investigations allow better understanding of the operation mechanism of the sense of smell. Progress in this field is crucial for the development of sensor technology based on olfaction-inspired biomaterials, which simulate the olfactory system of the biological counterparts. The biosensor matrices with a receptor layer which simulates biological sense of smell are successfully implemented in the construction of the devices classified as bioelectronic noses. Development of the technique of ‘electronic/artificial noses’ such as bioelectronic nose instruments (bioelectronic nose, biomimetic electronic nose, bio- enose, b- enose) foreshadows changes in more specific and sensitive odour analysis. Structure and operation mechanisms of biological olfactory systems are presented in this paper. A state of the art in the field of biosensing materials employed in biosensors and utilised for construction of the bioelectronic noses as well as future trends in smell recognition instruments are discussed. A summary of common methods used for the development and immobilization of materials based on the elements of the biological olfactory system is provided.收起
摘要 :
This paper provides an overview on graphene solution-gated field-effect transistors (SGFETs) and their applications in bioelectronics. The fabrication and characterization of arrays of graphene SGFETs is presented and discussed wi...
展开
This paper provides an overview on graphene solution-gated field-effect transistors (SGFETs) and their applications in bioelectronics. The fabrication and characterization of arrays of graphene SGFETs is presented and discussed with respect to competing technologies. To obtain a better understanding of the working principle of solution-gated transistors, the graphene–electrolyte interface is discussed in detail. The in vitro biocompatibility of graphene is assessed by primary neuron cultures. Finally, bioelectronic experiments with electrogenic cells are presented, confirming the suitability of graphene to record the electrical activity of cells.
收起
摘要 :
Recent measurements in poly(3,4-ethylenedioxy-thiophene): poly(styrene sulfonate) (PEDOT:PSS) films show that capacitance scales with film volume. We discuss the ramifications of this finding and propose a simple model that descri...
展开
Recent measurements in poly(3,4-ethylenedioxy-thiophene): poly(styrene sulfonate) (PEDOT:PSS) films show that capacitance scales with film volume. We discuss the ramifications of this finding and propose a simple model that describes capacitance in terms of sites in which ions injected from the electrolyte replace holes that are extracted from the film by a metal contact. We propose that volumetric capacitance is inversely proportional to the average distance between these sites. (C) 2016 Wiley Periodicals, Inc.
收起
摘要 :
Current bioelectronic medicines for neurological therapies generally involve treatment with a bioelectronic system comprising a power supply unit and a bioelectrode device. Further integration of wireless and self-powered units is...
展开
Current bioelectronic medicines for neurological therapies generally involve treatment with a bioelectronic system comprising a power supply unit and a bioelectrode device. Further integration of wireless and self-powered units is of practical importance for implantable bioelectronics. In this study, we developed biocompatible organic photovoltaics (OPVs) for serving as wireless electrical power supply units that can be operated under illumination with near-infrared (NIR) light, and organic bioelectronic interface (OBEI) electrode devices as neural stimulation electrodes. The OPV/OBEI integrated system is capable to provide electrical stimulation (ES) as a means of enhancing neuron-like PC12 cell differentiation and neurite outgrowth. For the OPV design, we prepared devices incorporating two photoactive material systems-beta-carotene/N,N'-dioctyl-3,4,9,10-perylenedicarboximide (beta-carotene/PTCDI-C8) and poly(3-hexylthiophene)/phenyl-C-61-butyric acid methyl ester (P3HT/PCBM)-that exhibited open circuit voltages of 0.11 and 0.49 V, respectively, under NIR light LED (NLED) illumination. Then, we connected OBEI devices with different electrode gaps, incorporating biocompatible poly(hydroxymethylated-3,4-ethyl-enedioxythiophene), to OPVs to precisely tailor the direct current electric field conditions during the culturing of PC12 cells. This NIR light-driven OPV/OBEI system could be engineered to provide tunable control over the electric field (from 220 to 980 mV mm(-1)) to promote 64% enhancement in the neurite length, direct the neurite orientation on chips, or both. The OPV/OBEI integrated systems under NIR illumination appear to function as effective power delivery platforms that should meet the requirements for wirelessly offering medical ES to a portion of the nervous system; they might also be a key technology for the development of next-generation implantable bioelectronics.
收起
摘要 :
Proteins have been shown to be electrically conductive if tethered to an electrode by means of a specific binding agent, allowing single molecules to be wired into an electrical sensing circuit. Such circuits allow enzymes to be u...
展开
Proteins have been shown to be electrically conductive if tethered to an electrode by means of a specific binding agent, allowing single molecules to be wired into an electrical sensing circuit. Such circuits allow enzymes to be used as sensors, detectors, and sequencing devices. We have engineered contact points into a Phi 29 polymerase by introducing biotinylatable peptide sequences. The modified enzyme was bound to electrodes functionalized with streptavidin. Phi 29 connected by one biotinylated contact, and a second nonspecific contact showed rapid small fluctuations in current when activated. Signals were greatly enhanced with two specific contacts. Features in the distributions of DC conductance increased by a factor 2 or more over the open to closed conformational transition of the polymerase. Polymerase activity is manifested by a rapid (millisecond) large (25% of background) current fluctuations imposed on the DC conductance.
收起
摘要 :
Abstract Studies have provided evidence that human cerebral organoids (hCOs) recapitulate fundamental milestones of early brain development, but many important questions regarding their functionality and electrophysiological prope...
展开
Abstract Studies have provided evidence that human cerebral organoids (hCOs) recapitulate fundamental milestones of early brain development, but many important questions regarding their functionality and electrophysiological properties persist. High-density microelectrode arrays (HD-MEAs) represent an attractive analysis platform to perform functional studies of neuronal networks at the cellular and network scale. Here, we use HD-MEAs to derive large-scale electrophysiological recordings from sliced hCOs. We record the activity of hCO slices over several weeks and probe observed neuronal dynamics pharmacologically. Moreover, we present results on how the obtained recordings can be spike-sorted and subsequently studied across scales. For example, we show how to track single neurons across several days on the HD-MEA and how to infer axonal action potential velocities. We also infer putative functional connectivity from hCO recordings. The introduced methodology will contribute to a better understanding of developing neuronal networks in brain organoids and provide new means for their functional characterization.Impact statement Human cerebral organoids (hCOs) represent an attractive in vitro model system to study key physiological mechanisms underlying early neuronal network formation in tissue with healthy or disease-related genetic backgrounds. Despite remarkable advances in the generation of brain organoids, knowledge on the functionality of their neuronal circuits is still scarce. Here, we used complementary metal-oxide-semiconductor (CMOS)-based high-density microelectrode arrays (HD-MEAs) to perform large-scale recordings from sliced hCOs over several weeks and quantified their activity across scales. Using single-cell and network metrics, we were able to probe aspects of hCO neurophysiology that are more difficult to obtain with other techniques, such as patch clamping (lower yield) and calcium imaging (lower temporal resolution). These metrics included, for example, extracellular action potential (AP) waveform features and axonal AP velocity at the cellular level, as well as functional connectivity at the network level. Analysis was enabled by the large sensing area and the high spatiotemporal resolution provided by HD-MEAs, which allowed recordings from hundreds of neurons and spike sorting of their activity. Our results demonstrate that HD-MEAs provide a multi-purpose platform for the functional characterization of hCOs, which will be key in improving our understanding of this model system and assessing its relevance for translational research.Graphical abstract
收起
摘要 :
The pace of research and development in neuroscience, neurotechnology, and neurorehabilitation is rapidly accelerating, with the number of publications doubling every 4.2 years. Maintaining this progress requires technological sta...
展开
The pace of research and development in neuroscience, neurotechnology, and neurorehabilitation is rapidly accelerating, with the number of publications doubling every 4.2 years. Maintaining this progress requires technological standards and scientific reporting guidelines to provide frameworks for communication and interoperability. The present lack of such neurotechnology standards limits the transparency, repro-ducibility, and meta-analysis of this growing body of literature, posing an ongoing barrier to research, clinical, and commercial objectives. Continued neurotechnological innovation requires the development of some minimal standards to promote integration between this broad spectrum of technologies and therapies. To preserve design freedom and accelerate the translation of research into safe and effective technologies with maximal user benefit, such standards must be collaboratively codeveloped by the full range of neuroscience and neurotechnology stakeholders. This paper summarizes the preliminary recommendations of IEEE P2794 Standards Working Group, developing a Reporting Standard for in-vivo Neural Interface Research (RSNIR).
收起
摘要 :
Advances in material science techniques and pioneering circuit designs have led to the development of electronic membranes that can form intimate contacts with biological tissues. In this review, we present the range of geometries...
展开
Advances in material science techniques and pioneering circuit designs have led to the development of electronic membranes that can form intimate contacts with biological tissues. In this review, we present the range of geometries, sensors, and actuators available for custom configurations of electronic membranes in cardiac applications. Additionally, we highlight the desirable mechanics achieved by such devices that allow the circuits and substrates to deform with the beating heart. These devices unlock opportunities to collect continuous data on the electrical, metabolic, and mechanical state of the heart as well as a platform on which to develop high definition therapeutics. (C) 2014 Elsevier Ltd. All rights reserved.
收起
摘要 :
The ongoing SARS-CoV-2 pandemic has emphasized the importance of technologies to rapidly detect emerging pathogens and understand their interactions with hosts. Platforms based on the combination of biological recognition and elec...
展开
The ongoing SARS-CoV-2 pandemic has emphasized the importance of technologies to rapidly detect emerging pathogens and understand their interactions with hosts. Platforms based on the combination of biological recognition and electrochemical signal transduction, generally termed bioelectrochemical platforms, offer unique opportunities to both sense and study pathogens. Improved bio-based materials have enabled enhanced control over the biotic-abiotic interface in these systems. These improvements have generated platforms with the capability to elucidate biological function rather than simply detect targets. This advantage is a key feature of recent bioelectrochemical platforms applied to infectious disease. Here, we describe developments in materials for bioelectrochemical platforms to study and detect emerging pathogens. The incorporation of host membrane material into electrochemical devices has provided unparalleled insights into the interaction between viruses and host cells, and new capture methods have enabled the specific detection of bacterial pathogens, such as those that cause secondary infections with SARS-CoV-2. As these devices continue to improve through the merging of hi-tech materials and biomaterials, the scalability and commercial viability of these devices will similarly improve.
收起
摘要 :
Recently, bioelectronic devices extensively researched and developed through the convergence of flexible biocompatible materials and electronics design that enables? more precise diagnostics and therapeutics in human health care a...
展开
Recently, bioelectronic devices extensively researched and developed through the convergence of flexible biocompatible materials and electronics design that enables? more precise diagnostics and therapeutics in human health care and opens up the potential to expand into various fields, such as clinical medicine and biomedical research. To establish an accurate and stable bidirectional bio‐interface, protection against the external environment and high mechanical deformation is essential for wearable bioelectronic devices. In the case of implantable bioelectronics, special encapsulation materials and optimized mechanical designs and configurations that provide electronic stability and functionality are required for accommodating various organ properties, lifespans, and functions in the biofluid environment. Here, this study introduces recent developments of ultra‐thin encapsulations with novel materials that can preserve or even improve the electrical performance of wearable and implantable bio‐integrated electronics by supporting safety and stability for protection from destruction and contamination as well as optimizing the use of bioelectronic systems in physiological environments. In addition, a summary of the materials, methods, and characteristics of the most widely used encapsulation technologies is introduced, thereby providing a strategic selection of appropriate choices of recently developed flexible bioelectronics.
收起