摘要 :
This paper examines a novel approach for temporal calibration of a three-dimensional (3-D) freehand ultrasound system. A localization system fixed on the probe gives the position and orientation of the probe. For quantitative use,...
展开
This paper examines a novel approach for temporal calibration of a three-dimensional (3-D) freehand ultrasound system. A localization system fixed on the probe gives the position and orientation of the probe. For quantitative use, calibration is needed to correctly localize a$B$-scan in four-dimensional (4-D) (3-D+t) space. Temporal latency estimation is defined in a general robust formulation using no specific probe motion constraints. Experiments were performed on synthetic and real data using a 3-D freehand ultrasound system. The achieved precision is lower than the image acquisition rate (40 ms). A validation study using a calibration phantom has been performed to evaluate the influence of incorrect latency estimation on the 3-D reconstruction procedure. We showed that for latency estimation errors less than 40 ms, the 3-D reconstruction errors are negligible for volume estimation.
收起
摘要 :
Three-dimensional (3D) ultrasound is an invaluable tool in the detection and evaluation of many uterine anomalies and improves upon the traditional approach of two-dimensional (2D) ultrasonography. We aim to describe an easy way o...
展开
Three-dimensional (3D) ultrasound is an invaluable tool in the detection and evaluation of many uterine anomalies and improves upon the traditional approach of two-dimensional (2D) ultrasonography. We aim to describe an easy way of assessing the uterine coronal plane using the basic three-dimensional ultrasound in everyday gynecological practice.
收起
摘要 :
Background: Whether infants use suction or peristaltic tongue movements or a combination to extract milk during breast-feeding is controversial. The aims of this pilot study were 1] to evaluate the feasibility of using 3D ultrasou...
展开
Background: Whether infants use suction or peristaltic tongue movements or a combination to extract milk during breast-feeding is controversial. The aims of this pilot study were 1] to evaluate the feasibility of using 3D ultrasound scanning to visualise infant tongue movements; and 2] to ascertain whether peristaltic tongue movements could be demonstrated during breast-feeding. Methods: 15 healthy term infants, aged 2. weeks to 4. months were scanned during breast-feeding, using a real-time 3D ultrasound system, with a 7. MHz transducer placed sub-mentally. Results: 1] The method proved feasible, with 72% of bi-plane datasets and 56% of real-time 3D datasets providing adequate coverage [>. 75%] of the infant tongue. 2] Peristaltic tongue movement was observed in 13 of 15 infants [83%] from real-time or reformatted truly mid-sagittal views under 3D guidance. Conclusions: This is the first study to demonstrate the feasibility of using 3D ultrasound to visualise infant tongue movements during breast-feeding. Peristaltic infant tongue movement was present in the majority of infants when the image plane was truly mid-sagittal but was not apparent if the image was slightly off the mid-sagittal plane. This should be considered in studies investigating the relative importance of vacuum and peristalsis for milk transfer.
收起
摘要 :
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US syst...
展开
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology).
收起
摘要 :
This paper evaluates five 3D ultrasound tracking algorithms regarding their ability to quantify abnormal deformation in timing or amplitude. A synthetic database of B-mode image sequences modeling healthy, ischemic and dyssynchron?Pub>...
展开
This paper evaluates five 3D ultrasound tracking algorithms regarding their ability to quantify abnormal deformation in timing or amplitude. A synthetic database of B-mode image sequences modeling healthy, ischemic and dyssynchrony cases was generated for that purpose. This database is made publicly available to the community. It combines recent advances in electromechanical and ultrasound modeling. For modeling heart mechanics, the Bestel–Clement–Sorine electromechanical model was applied to a realistic geometry. For ultrasound modeling, we applied a fast simulation technique to produce realistic images on a set of scatterers moving according to the electromechanical simulation result. Tracking and strain accuracies were computed and compared for all evaluated algorithms. For tracking, all methods were estimating myocardial displacements with an error below 1 mm on the ischemic sequences. The introduction of a dilated geometry was found to have a significant impact on accuracy. Regarding strain, all methods were able to recover timing differences between segments, as well as low strain values. On all cases, radial strain was found to have a low accuracy in comparison to longitudinal and circumferential components.
收起
摘要 :
We present a new method for three-dimensional (3-D) visualization and identification of biological microorganisms using partially temporal incoherent light in-line (PTILI) computational holographic imaging and multivariate statist...
展开
We present a new method for three-dimensional (3-D) visualization and identification of biological microorganisms using partially temporal incoherent light in-line (PTILI) computational holographic imaging and multivariate statistical methods. For 3-D data acquisition of biological microorganisms, the band-pass filtered white light is used to illuminate a biological sample. The transversely and longitudinally diffracted pattern of the biological sample is magnified by microscope objective (MO) and is optically recorded with an image sensor array interfaced with a computer. Three-dimensional reconstruction of the biological sample from the diffraction pattern is accomplished by using computational Fresnel propagation method. Principal components analysis and nonparametric inference algorithms are applied to the 3-D complex amplitude biological sample for identification purposes. Experiments indicate that the proposed system can be useful for identifying biological microorganisms. To the best of our knowledge, this is the first report on using PTILI computational holographic microscopy for identification of biological microorganisms.
收起
摘要 :
BackgroundTo describe the clinical set-up and evaluate the feasibility of multimodal ultrasound tomography (MUT) for breast imaging.MethodsThirty-two consecutive patients referred for breast imaging and 24 healthy volunteers under...
展开
BackgroundTo describe the clinical set-up and evaluate the feasibility of multimodal ultrasound tomography (MUT) for breast imaging.MethodsThirty-two consecutive patients referred for breast imaging and 24 healthy volunteers underwent MUT. In the 32 patients, the examination discomfort was compared to that of mammography (n?=?31), handheld ultrasound (HUS) (n?=?27) and magnetic resonance imaging (MRI) (n?=?4) on a scale from 1 (lowest discomfort) to 10 (highest discomfort). MUT investigation time was recorded. Findings automatically detected by MUT were correlated with conventional imaging and biopsy results.ResultsBreast MUT was well tolerated by all 56 participants; 55 bilateral exams were uneventful. During one exam, the digitalisation card failed and the exam was successfully repeated within three days. Mean examination discomfort was 1.6 (range?=?1–5) for MUT, 1.5 (range?=?1–5) for HUS, 5.3 (range?=?3–7) for MRI, and 6.3 (range?=?1–10) for mammography. MUT examination time was 38?±?6?min (mean?±?standard deviation). In the patients referred for breast imaging, MUT detected four lesions and indicated malignancy in three of these cases. These findings were confirmed by additional imaging and biopsy.ConclusionMUT is feasible in a clinical context considering examination time and patient acceptance. These interesting initial diagnostic findings warrant further studies.
收起
摘要 :
Facial information is a powerful channel for human-to-human communication. Characteristically, faces can be defined as biological objects that are four-dimensional (4D) patterns, whereby they have concurrently a spatial structure ...
展开
Facial information is a powerful channel for human-to-human communication. Characteristically, faces can be defined as biological objects that are four-dimensional (4D) patterns, whereby they have concurrently a spatial structure as well as temporal dynamics. The spatial characteristics of facial objects possess three dimensions (3D), namely breadth, height and importantly, depth. The temporal properties of facial objects are defined by how a 3D facial structure evolves dynamically over time; where time is referred to as the fourth dimension (4D). Our entire perspective of another’s face, whether it be social, affective or cognitive perceptions, is therefore built on a combination of 3D and 4D visual cues. Counterintuitively, over the past few decades of experimental research in psychology, facial stimuli have largely been presented to participants as a spatial pattern that has been flattened into two dimensions (2D), while remaining largely static. The following review aims to advance and update facial researchers, on the recent revolution in computer-generated, realistic 4D facial models produced from real-life human subjects. We delve in-depth to summarize recent studies which have utilized facial stimuli that possess 3D structural cues (geometry and depth) and 4D temporal cues (3D structure + dynamic viewpoint and movement). In sum, we have found that higher-order perceptions such as identity, gender, ethnicity, emotion and personality, are critically influenced by the 4D characteristics embedded within natural human faces. In future, it is recommended that facial stimuli incorporate the 4D space-time perspective with the proposed time-resolved methods.
收起
摘要 :
We propose a novel global optimization-based approach to segmentation of 3-D prostate transrectal ultrasound (TRUS) and T2 weighted magnetic resonance (MR) images, enforcing inherent axial symmetry of prostate shapes to simultaneo...
展开
We propose a novel global optimization-based approach to segmentation of 3-D prostate transrectal ultrasound (TRUS) and T2 weighted magnetic resonance (MR) images, enforcing inherent axial symmetry of prostate shapes to simultaneously adjust a series of 2-D slice-wise segmentations in a “global” 3-D sense. We show that the introduced challenging combinatorial optimization problem can be solved globally and exactly by means of convex relaxation. In this regard, we propose a novel coherent continuous max-flow model (CCMFM), which derives a new and efficient duality-based algorithm, leading to a GPU-based implementation to achieve high computational speeds. Experiments with 25 3-D TRUS images and 30 3-D T2w MR images from our dataset, and 50 3-D T2w MR images from a public dataset, demonstrate that the proposed approach can segment a 3-D prostate TRUS/MR image within 5–6 s including 4–5 s for initialization, yielding a mean Dice similarity coefficient of $93.2%pm 2.0%$ for 3-D TRUS images and $88.5%pm 3.5%$ for 3-D MR images. The proposed method also yields relatively low intra- and inter-observer variability introduced by user manual initialization, suggesting a high reproducibility, independent of observers.
收起